Introduction to the Fly Facility
This page is also available as a pdf
If you are new to Genetics and would like to use the Fly Facility, please contact John Roote (jr32) to arrange an induction. In advance of this we would like you to read the appropriate safety documentation and our Welcome page and this Introduction to the Fly Facility, which explain the rules for using the facility. Risk assessments and standard operating procedures (SOPs) are in the Safety folder on the desktop of the fly lab iMac or you can download them from CamTools. If any of your work is not covered by these risk assessments please write your own.
At the end of your induction we will ask you to sign a form [see end of this page] to confirm that you have read and understood the fly lab rules and the risk assessments.
The lab
Hint: We have a policy of discarding old flies without consultation, so if you ignore everything else in this Introduction please be sure to read the Rules for fly culturing!
All fly handling in the department is carried out in the fly lab, which is situated in room 115 on the first floor. There are four constant temperature rooms within the fly lab: CT 2 and CT 3 at 18o, CT 1 and CT 4 at 25o; all have 65-75% humidity. There is also a micro-injection room, which is maintained at 18o and ambient humidity.
The CT rooms have pullout double-depth shelves on one side and single-depth fixed shelves on the other. (Take care: The pullout shelves are heavy. If they stick, try lifting them gently.)
There are 24 workstations in the fly lab. About 8-10 of these are used by full-time fly pushers, but since the lab is a communal resource all workstations are available when vacant. It is essential, however, to clean the bench and microscope and surrounding area (including beneath equipment) after every use, with alcohol or Mr Muscle.. Please leave the workstations cleaner than you found them and free of all fly cultures, equipment and rubbish.
Microscope lenses can be cleaned with alcohol and lens tissue only, never with Kleenex. Boxes of lens tissues are located at the end of each bench.
Do not store fly cultures or media on the bench, or leave anything on the bench other than basic fly-pushing equipment. Clean up spills and broken glass.
Please keep your own set of fly-pushing tools: brush, funnel, marker pen, etc.
Noise
Fly pushing can be a noisy occupation if done incorrectly. With 24 people banging vials and bottles on the bench the lab could become a very unattractive place to work. Banging also causes the media to fall out and the flies to stick to the media and it damages microscopes and light boxes.
Please ask to be shown the correct, noise-free fly-handling techniques.
Hint: rather than transferring your flies directly from a culture bottle to the CO2 plate it is quicker and quieter to knock them into a clean plastic tube first (using a funnel) and then inject CO2 into this tube before tipping the unconscious flies onto the pad.
Hint: Consider knocking the fly container gently on your knee or tapping with your finger rather than on the bench.
CO2
CO2 is stored in large cylinders in a shed outside the department. The gas pressure is regulated to a safe working pressure and piped to the lab where the pressure is further reduced in the lab by the main CO2 control valve (a black tap situated by the window, behind the media storage cupboards).
If you are the last person to leave the lab in the evening please turn this tap off. Similarly you will need to turn it on if you are first to arrive in the morning.
OFF: turn the black tap 1/4 turn clockwise (tap will be at right angles to the pipe)
ON: turn the black tap 1/4 turn anti-clockwise (tap will be in line with the pipe)
Do not touch the yellow pressure regulator (diaphragm valve).
There is a panel near the door that sounds an alarm and shows a red light if one of the banks of cylinders is empty. Please mute the alarm and inform a member of the fly facility.
The CO2 pads are made of porous polythene stuck into Perspex blocks. This membrane is easily crushed. Do not bang tubes or bottles on the surface. We have a supply of blanks cut to fit the small pads. Please replace them every few weeks or when they become dirty or inefficient, smooth side up.
Every workstation has its own gas control tap. Turn the tap on until the green indicator is just showing. Keep the gas flow to a minimum at all times; the pads are efficient and a very low flow is sufficient to keep the flies asleep. Once you have knocked the flies out turn the flow down to the minimum necessary to stop the flies walking away. (Flies dehydrate and die more quickly if the gas flow is high.)
Please remember to turn your CO2 tap off when not in use.
The bubblers are essential to prevent your flies from becoming dehydrated when anaesthetised. Check them regularly to ensure that they are working efficiently and do not leak. Ensure the rubber bung is pushed fully in, replace parts and refill with water as necessary.
Natural gas
There are 2 gas taps at the window-end of each bench. The taps are spring-loaded – when you have finished using gas check that they are turned off properly. If in doubt turn the isolation valve off - this is located in the first bay as you enter the lab, by the window, at low level.
Morgues
Morgues are simply a bottle of alcohol with a funnel. When necessary flush the contents down the sink with plenty of water. Clean the funnel and the sink. Refill bottle with a little alcohol from the yellow flammables cupboard.
Media
Media can be requested 24 hours in advance via the website on http://www.cam.ac.uk/~icc20/media. You will need an @cam.ac.uk email address and a Raven password to access the website [see http://raven.cam.ac.uk]. If you do not have a local email address please ask a colleague in your group to order media for you.
The media technicians prepare media between 8 am and 11 am Monday to Friday. When it has cooled and dried they plug the media, seal it in plastic bags and, by late afternoon, deliver it to the media cupboards in the fly lab. .
Media Storage
The blue cupboards at the near end of the fly lab are used for storing media. Please store media in sealed poly bags, labelled with your name and the date of preparation. Do not store it here for longer than 7 days. Old or unlabelled media will be discarded after 10 days.
Please do not store media in the CT rooms, particularly on the floor where mites lurk.
If you want to store media for longer periods (up to 3 weeks) there is a 4o room in the basement (B6). Media will dehydrate rapidly at 4o unless sealed in poly bags. Label it with your name and the date on which it was prepared.
Hint: You cannot use fly media at 4o - flies are paralysed at low temp and stick to the surface of the media - allow the media to warm up at room temperature for 3-4 hours.
Hint: If you need to make your own media, saucepans of various sizes and a gas hob are available in B2. The ingredients, glassware and trays are stored in B2, B18 and in cupboards in the corridor. Recipes are in the front of the order books. Please leave the bench, sink, utensils and gas hob spotless (cleaner than you found them!).
READ THE FOLLOWING SECTION!!
Rules for fly culturing
Please label all fly cultures clearly so that we can easily identify the owner and the date on which they were set up.
Hint: When transferring flies from 18o to 25o or 25o to 18o it would be helpful if you noted the date of transfer on the label at the front of the tray.
Each week we inspect the CT rooms. If we discover trays of flies in which there are old cultures or trays that are not properly labelled, the whole tray will be removed to the SIN BIN trolley (next to the fume hood at the back of the fly lab). Your flies will remain there for 3 days and will then be discarded. Do not move flies from the sin bin back into the CT rooms without first checking them for mites and mould and transferring them to new media.
Hints: Transfer stocks to clean trays, never re-use them. Stack used trays on the trolleys provided.
Do not store flies on the CT room floors, always use the shelves. Mites love floors.
25o stocks should be transferred and the old cultures discarded every 2 weeks. It may be desirable to keep cultures for a little longer (e.g. when collecting virgins, scoring crosses, screens, etc.), but generally flies cease to emerge from most cultures after 16-18 days. In exceptional circumstances cultures may be kept for 20 days. But note: all cultures exceeding 20 days old will be moved to the sin bin
18o stocks should be transferred every 4-5 weeks. Again it may occasionally be necessary to keep cultures for longer but generally flies have ceased to emerge from 18o cultures after 35 days. In exceptional circumstances they may be kept for 40 days. Note: all cultures exceeding 40 days old will be moved to the sin bin.
Discards
Discard-trolleys are kept in the Fly Lab and are collected by the glassware cleaners at regular intervals. Place used tubes in the top, bottles in the bottom.
Mites
All stocks should be checked regularly for mites, mould and other contaminants. If you do not know what mites look like
1) ask somebody
2) see the photos on the fly lab notice board (not actual size)
3) read the chapter on Parasites, Pests and Diseases in the Ashburner volume: A Laboratory Handbook (p1285)
4) go to the Bloomington Stock Center website: http://flystocks.bio.indiana.edu/Fly_Work/culturing.htm
What to do if you find mites in your lab stocks
1) Tell John Roote or another permanent member of the fly lab
2) Discard all non-essential stocks
3) Replace foam stoppers with cotton wool or Flugs. Mop all potentially mitey surfaces (including the CT room shelves) with alcohol.
4) For badly affected stocks: move the flies to the isolation room, select 5-10 pairs of clean adults (check them for mites and mite eggs) to set up a new culture; transfer the adults 3 times, once every 2-3 days, discard the first 2 transfers; continue to check the stock for at least 2 generations.
5) For less affected stocks: rapid transfer, transfer adults to new vials every 2 days, at least 3 times. Discard the early transfers.
Quarantine
(see “Mites and Quarantine” download for full protocol)
If you bring new stocks into the department from whatever source they must be quarantined in the isolation area in the attic for a minimum of 2 generations (i.e. 2 'clean' generations. Please do not attempt to shortcut this procedure.
EMS
Chemical mutagenesis can be carried out in the fume hood in the fly lab. Please ask for a protocol.
X-ray
John Roote will show you how to use the Torrex X-ray machine, situated in the basement. Do not use it without training.
Cage room
There is an embryo collection facility in the basement (room B14a). If you wish to use this facility please discuss your requirements with Hayden McDermott beforehand (tel 33970, email hm265).
Allergies
A very small number of people who are exposed to Drosophila develop allergies. Consequently soon after you start working in the fly lab you will receive a letter from the Occupational Health Service (OHS) asking you to attend a health screening appointment with a nurse. The appointment will be brief and completely noninvasive. You will be asked to fill-in a questionnaire and blow into a tube. Please inform us if you have an existing allergy that might predispose you to a fly allergy. If you are concerned that you are developing symptoms contact OHS (Tel: 36594) who will monitor you and advise accordingly. Protective clothing including masks (FFP1 and FFP2) and gloves are available in the fly lab. Please inform us of your requirements.
Risk Assessments and SOPs
Risk assessments and SOPs relevant to fly workers are kept in the Safety box-file (purple) in the fly laband can also be found in the safety folder on the desktop of the fly lab iMac. If your work is not covered by these risk assessments please write youtr own.
Please read whichever are appropriate for your work. If you are using, or intend to use, techniques that are not covered by this list you MUST write your own risk assessment. .
Posture
See: http://www.microscopyu.com/articles/ergonomics/ergointro.html, http://www.working-well.org/articles/archive.html#lab and other articles from http://www.working-well.org/
If you use a microscope for a "significant part of your working day" please read these documents. Also please read the recommendations for vdu use in the department safety handbook (pages 25-27)
Printouts of all these documents can be found in the fly lab SAFETY box file.
If you have any problems which you think are related to microscope or vdu use do not hesitate to tell your group leader or John Roote
Fly stock lists
Our core collection of stocks is available free to Cambridge flypushers. The list can be downloaded from this website. Some fly groups have published their stock lists on the fly lab Mac in the desktop folder 'current stock lists'. Please put your stock list here too.
..and finally
If you are new to fly work or need help or advice please feel free to ask John Roote or one of the fly facility technicians. Our technicians are very experienced, and would be more than happy to answer any questions that arise.
“Fly Pushing. The Theory and Practice of Drosophila Genetics” by Ralph Greenspan is a very good introduction for beginners. See the Welcome page on the website for a full list of fly books available for loan from the fly lab.
The Bloomington web pages http://flystocks.bio.indiana.edu provide much useful information for beginners and old hands alike.
Now please fill in this form and return it to John Roote. Or you can get a pdf of this page plus the form HERE. Don’t forget to add Fly Facility induction to your Personal Safety Training Record.
Page updated 29 November 2011
